Add to Enquiry
Z2000 ATEX Low Cost Tank Gauge Series added to enquiry
Z2000 ATEX  Low Cost Tank Gauge Series
Z2000 ATEX Low Cost Tank Gauge Series
Z2000

Z2000 Tank Gauge is a kit for use with hazardous products. The sensor is suitable for ATEX Zone 0/1 and the Gauge unit for Zone 2 / Safe area. (It can be outside in all weathers)

Product Options
List
Z2000-A-ATEX-A12 Z2000-A-ATEX-A12 Tank Gauge kit 3 meter sensor
£727.00
Z2000-A-ATEX-A14 Z2000-A-ATEX-A14 Tank Gauge kit 5 meter sensor
£727.00
Z2000-A-ATEX-A16 Z2000-A-ATEX-A16 Tank Gauge kit 10 meter sensor
£779.00
CALIB-Z2000 Calibration of Z2000 Gauge based on client supplied dimensions
£16.10
Z2000-A Z2000 Mirror Gauge unit Zone 2 with Barrier protection
£420.80
Add to Enquiry
Z2000 ATEX Low Cost Tank Gauge Series added to enquiry
Specification

This range of Gauges has the following system Options.

 

Z2000-A-ATEX-A12 is a kit for tanks up to 3 meters high. 10 meter cable

Z2000-A-ATEX-A14 is a kit for tanks up to 5 meters high. 10 meter cable

Z2000-A-ATEX-A16 is a kit for tanks up to 10 meters high. 10 meter cable

 

The probe can be installed in Zone 0/1 ( submerged in the product or in the vapour)

The Gauge unit must be in a Zone 2 / Safe area. It is fully weatherproof for outdoor use.

Application

Products that this range is ideal for are.

Diesel

Kerosene

Screen Wash ( alcohol in this makes it flamable)

Spirits

Petrol (vented Tanks without Vapour recovery)

Case Studies

When Diesel was reclassified to hazardous, many manufactures ignored the ATEX regulations.

At OLE we feel we should offer customers the option of using standard non certified gauges or ATEX kits for Diesel.

It makes sense to use ATEX approved gauges for all hazardous products such as Kerosene and Screen Wash, as well as obviously hazardous products such as Petrol.

 

Risk assessments should be performed on a job for job basis, and a descision made as to whether ATEX zoned conditions could apply.

FAQ

When Diesel was reclassified to hazardous, many manufactures ignored the ATEX regulations.

At OLE we feel we should offer customers the option of using standard non certified gauges or ATEX kits for Diesel.

It makes sense to use ATEX approved gauges for all hazardous products such as Kerosene and Screen Wash.

 

Risk assessments should be performed on a job for job basis, and a descision made as to whether ATEX zoned conditions could apply.

 

Q/     How do I set the Tank Sensor Span in the Gauge

A/     Scroll through to section 10 and 11 in the SET-UP Instructions.  These  are either A12, A14, A16, A18, A20 probes.